EasyManua.ls Logo

AUMA SAREx 07.2 - Page 9

AUMA SAREx 07.2
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Approval plate in explosion-proof version
Figure 3: Approval plates in explosion-proof version (examples)
[1] Ex symbol
[2] Number of test authority
[3] Classification:
Division 1 (frequency or duration of occurrence of hazardous substances)
Class I = Gasses, vapors or liquids (groups B, C, D)
Class II = Combustible dusts (groups E, F, G)
Class II = Fibers and Flyings
[4] Protection type of housing
[5] Temperature class / max. surface temperature
[6] Permissible ambient temperature
[7] Number of certificate (for CSA only)
Description referring to name tag indications
Type designation Figure 4: Type designation (example)
1. Type and size of actuator
2. Flange size
3. Ex marking
Type and size
This manual applies to the following device types and sizes:
Multi-turn actuators for open-close duty: SAEx 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
Multi-turn actuators for modulating duty: SAREx 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
9
SAEx 07.2 SAEx 16.2 / SAREx 07.2 SAREx 16.2
Identification

Table of Contents

Other manuals for AUMA SAREx 07.2

Related product manuals