EasyManua.ls Logo

AUMA SAREx 07.6 User Manual

AUMA SAREx 07.6
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Control
Parallel
Profibus DP
Profinet
Modbus RTU
Modbus TCP/IP
Foundation Fieldbus
HART
Multi-turn actuators
SAEx 07.2 SAEx 16.2
SAREx 07.2 SAREx 16.2
Control unit - electromechanical
with actuator controls
ACExC 01.2 Intrusive
Assembly and commissioningOperation instructions

Table of Contents

Other manuals for AUMA SAREx 07.6

Question and Answer IconNeed help?

Do you have a question about the AUMA SAREx 07.6 and is the answer not in the manual?

AUMA SAREx 07.6 Specifications

General IconGeneral
BrandAUMA
ModelSAREx 07.6
CategoryController
LanguageEnglish

Summary

Safety Instructions

Prerequisites for Safe Handling

Ensures compliance with regulations for assembly, electrical connection, commissioning, and operation.

Warnings and Notes

Explains safety-relevant procedures and signal words (DANGER, WARNING, CAUTION, NOTICE).

Short Description of Actuators

Multi-turn Actuator Overview

Defines multi-turn actuators and describes AUMA's SAEx/SAREx models.

Actuator Assembly

Mounting Actuator to Valve

Step-by-step guide for attaching actuators to valves, including output drive types.

Electrical Connection

Basic Electrical Information

Covers safety warnings, wiring diagrams, and permissible network types.

AUMA Electrical Connection Types

Overview of KT/KM, KP/KPH, and KES electrical connection versions.

Operation Procedures

Manual Valve Operation

Describes how to operate the actuator manually using the handwheel.

Actuator Operation from Local Controls

Explains how to operate the actuator using the push buttons on the control unit.

Indications and Status Signals

Display Indications

Explains status bar, navigation support, and feedback signals like valve position.

Commissioning Basic Settings

Type of Seating Setting

Procedure for setting the valve seating type (limit or torque).

Fieldbus Settings

Configuration of Modbus address, baud rate, parity, and monitoring time.

Torque and Limit Switching

Instructions for setting torque switching and limit switches for end positions.

Test Run Procedures

Steps for performing test runs, checking rotation direction, and limit switching.

Commissioning Optional Equipment

Corrective Actions

Faults During Commissioning

Troubleshooting common faults encountered during commissioning.

Servicing and Maintenance

Disconnection from Mains

Procedures for disconnecting the actuator from power for maintenance.

Related product manuals