EasyManua.ls Logo

AUMA SAEx 07.6 - User Manual

AUMA SAEx 07.6
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Control
Parallel
Profibus DP
Profinet
Modbus RTU
Modbus TCP/IP
Foundation Fieldbus
HART
Multi-turn actuators
SAEx 07.2 SAEx 16.2
SAREx 07.2 SAREx 16.2
Control unit - electromechanical
with actuator controls
ACExC 01.2 Intrusive
Assembly and commissioningOperation instructions

Table of Contents

Other manuals for AUMA SAEx 07.6

Question and Answer IconNeed help?

Do you have a question about the AUMA SAEx 07.6 and is the answer not in the manual?

AUMA SAEx 07.6 Specifications

General IconGeneral
BrandAUMA
ModelSAEx 07.6
CategoryController
LanguageEnglish

Summary

Safety Instructions

Prerequisites for Safe Handling

Requirements for safe handling, including standards, personnel qualification, and specific conditions.

Range of Application

Defines where the actuators are designed for use, including zones and permitted/not permitted applications.

Warnings and Notes

Explains safety-relevant symbols (DANGER, WARNING, CAUTION, NOTICE) and their meanings.

Assembly

Mount Actuator to Valve

Steps for mounting the actuator onto the valve.

Electrical Connection

Basic Information

General safety warnings and information regarding electrical connections and mains voltage.

KT;KM Electrical Connection

Details on the KT/KM electrical connection types and their properties.

KP;KPH Electrical Connection

Details on the KP/KPH electrical connection types and their features.

KES Electrical Connection

Details on the KES electrical connection types and their technical data.

Operation

Manual Operation

Procedures for operating the actuator manually for setup and emergency use.

Motor Operation

Information on operating the actuator via its electric motor.

Indications

Feedback Signals from Actuator and Valve

How valve position and operation direction are indicated on the display.

Status Indications According to AUMA Classification

Explanation of status codes (S0005, S0006, S0007) for warnings, not ready, and faults.

Status Indications According to NAMUR Recommendation

Explanation of NAMUR status codes (S0008-S0011) for out of specification, function check, and maintenance.

Commissioning (Basic Settings)

Type of Seating: Set

How to set the type of seating (limit or torque) for end positions.

Limit Switching: Set

Procedures for setting the limit switches for end positions.

Test Run

Performing test runs after settings are completed.

Commissioning (Optional Equipment Settings)

EWG 01.1 Electronic Position Transmitter

Commissioning of the EWG 01.1 electronic position transmitter.

RWG Electronic Position Transmitter

Commissioning of the RWG electronic position transmitter.

Measuring Range: Set

How to set the measuring range for the RWG transmitter.

Corrective Action

Faults During Commissioning

Troubleshooting common faults encountered during commissioning.

Fault Indications and Warning Indications

Explains how faults and warnings are displayed and their impact.

Motor Protection (Thermal Monitoring)

How motor protection functions and how to test it.

Servicing and Maintenance

Preventive Measures for Servicing and Safe Operation

Routine checks and maintenance tasks for safe operation.

Technical Data

Technical Data Multi-turn Actuators

Detailed technical specifications for multi-turn actuators.

Technical Data Actuator Controls

Detailed technical specifications for actuator controls.

Related product manuals