EasyManua.ls Logo

AUMA SAR 6 User Manual

AUMA SAR 6
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the AUMA SAR 6 and is the answer not in the manual?

AUMA SAR 6 Specifications

General IconGeneral
BrandAUMA
ModelSAR 6
CategoryController
LanguageEnglish

Summary

Multi-turn Actuators

Multi-turn Actuator SA3 - SA100

Standard multi-turn actuator with torque range 3 m kg to 100 m kg and output speed 4 rpm to 180 rpm.

Multi-turn Actuator Integral Starter - Compact

Compact version of integral starter multi-turn actuator with local/remote control.

Multi-turn Actuator Integral Starter - e pac

Electronic version of integral starter multi-turn actuator with field programming.

Multi-turn Actuator Flame Proof / Explosion Proof

Actuator designed for hazardous or explosive areas, complying with flame proof standards.

Functions

Open Close Duty

Actuator operates to end positions in an open-loop system with infrequent operation.

Regulating / Modulating Duty

Actuator operates in a closed-loop system, adjusting valve position based on input signals.

Control Equipment

Micro Switches

Convert mechanical parameters (travel, torque) into electrical signals for actuator control.

Position Indicators

Includes mechanical indicators with discs and remote indicators via potentiometers.

Motors

Details 3-phase, single-phase AC, and DC motors used in actuators, including technical data.

Motor Protection

Thermo switches protect motor windings from overheating by interrupting the control circuit.

Actuators for Regulating Duty

Description of Regulating Duty

Details SAR actuators for regulating duty, highlighting differences from SA actuators and selection points.

Principle of Operation

Diagram and explanation of the closed-loop operation for regulating duty actuators.

Description of Electronic Units

Details electronic units like potentiometers and transducers used for position feedback.

Electronic Positioner CU01

Three-level positioner comparing input signals to control actuator operation via relays.

Actuator Types

Auma Norm Actuators

Standard actuator with electric motor, torque switch, limit switches, and blinker switch.

Auma Integral Starter Actuators

Actuators with integral controls to save installation costs, ready for use.

Auma Compact

Simpler Integral Starter Unit with selector switch and push buttons for local/remote control.

Auma e-pac

Electronic version with field programming, modular construction (Power, Relay, Control Modules).

Interface

Valve Attachment

Specifies valve attachment according to ISO 5210 or DIN 3210, including flange sizes and torque ratings.

Output Drives

Details various output drive types (Stem nut, Plug Sleeve, Dog Coupling, Stub Shaft, Bore with Keyway) according to ISO 5210/DIN 3210.

Electrical Connection

Details screw-type terminals and plug socket connectors for actuator wiring.

Actuator - Gear box Combinations

Details combinations with Worm, Bevel, and Lever Gear boxes to extend torque/speed ranges.

Service Conditions

Enclosure Protection

Details IP67 and IP68 enclosure protection standards for dust and water resistance.

Ambient Temperature

Specifies operating temperature ranges for different actuator types (SA, SAR, SAEX/SAREx/SACEx/SARCEx).

Explosion Proof / Flame Proof Actuators

Specifies protective measures for hazardous areas according to IS 2148-1981, tested and certified.

Technical Data: Open-Close Duty

Technical Data: Regulating Duty

Dimension Sheet: Norm Actuator

Dimension Sheet: Integral Starter Compact Actuator

Dimension Sheet: Integral Starter e-pac Actuator

Terminal Plan: Norm Actuator

Wiring Diagram: Integral Starter, e-pac

Legend: Integral Starter, e-pac

Related product manuals