Electrical Data
Open-Close duty
SA3-SA100
Nm
Torque
Max.
30
60
120
110
150
250
220
55
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.
1/min
Size
Auma India
Actuator Type
Three phase Squirrel cage AC Motor 415V, 50 Hz
Nominal
Output
KW
Speed
1/min
Nominal
Current
A
Starting
Current
A
Full load
Efficiency
(%)
Current at
Max. Torque
A
1)
Type
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
6
6
6
6
6
12
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
25
25
25
25
25
25
25
25
25
25
25
25
11
16
22
32
45
63
90
125
180
4
5.6
8
11
16
22
32
45
63
90
125
180
4
5.6
8
11
16
22
32
45
63
90
125
180
4
5.6
8
11
16
22
32
45
63
4
5.6
8
11
16
22
32
45
63
90
125
180
0.06
0.06
0.06
0.12
0.18
0.18
0.37
0.37
0.37
0.06
0.06
0.06
0.12
0.12
0.12
0.18
0.37
0.37
0.55
0.55
0.55
0.06
0.12
0.12
0.12
0.25
0.25
0.37
0.55
1.1
1.1
1.1
1.1
0.06
0.12
0.12
0.25
0.25
0.37
0.55
1.1
1.1
0.12
0.25
0.55
0.55
0.55
0.55
1.1
1.1
2.2
2.2
2.2
2.2
1400
1400
1400
1400
2800
2800
2800
2800
2800
1400
1400
1400
1400
1400
1400
2800
2800
2800
2800
2800
2800
1400
1400
1400
1400
1400
1400
2800
2800
2800
2800
2800
2800
1400
1400
1400
1400
1400
2800
2800
2800
2800
1400
1400
1400
1400
1400
1400
2800
2800
2800
2800
2800
2800
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
71
90
90
90
90
0.3
0.3
0.3
0.5
0.6
0.6
1.0
1.0
1.0
0.3
0.3
0.3
0.5
0.5
0.5
0.6
1.0
1.0
1.8
1.8
1.8
0.3
0.5
0.5
0.5
1.4
1.4
1.0
1.8
2.9
2.9
2.9
2.9
0.3
0.5
0.5
1.4
1.4
1.0
1.8
2.9
2.9
0.5
1.4
2.8
2.8
2.8
2.8
2.9
2.9
4.6
4.6
4.6
4.6
0.30
0.38
0.50
0.62
0.84
1.16
1.62
1.40
2.05
0.25
0.30
0.38
0.45
0.62
0.90
1.18
1.62
2.34
3.08
2.45
3.52
0.38
0.46
0.62
0.90
1.45
1.80
2.42
3.08
4.58
6.50
5.10
7.50
0.45
0.55
0.83
1.36
1.66
2.00
2.75
4.26
5.67
0.65
1.29
1.64
1.92
2.60
3.58
4.75
6.58
8.44
12.5
8.95
13.6
1.2
1.2
1.2
2.3
3.3
3.3
5.5
5.5
5.5
1.2
1.2
1.2
2.3
2.3
2.3
3.3
5.5
5.5
9.0
9.0
9.0
1.2
2.3
2.3
2.3
4.6
4.6
5.5
9.0
16.0
16.0
16.0
16.0
1.2
2.3
2.3
4.6
4.6
5.5
9.0
16.0
16.0
2.3
4.6
12.0
12.0
12.0
12.0
16.0
16.0
40.0
40.0
40.0
40.0
0.6
0.6
0.6
0.6
0.7
0.7
0.76
0.76
0.76
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.76
0.76
0.62
0.62
0.62
0.6
0.6
0.6
0.6
0.5
0.5
0.76
0.62
0.72
0.72
0.72
0.72
0.6
0.6
0.6
0.5
0.5
0.76
0.62
0.72
0.72
0.6
0.5
0.51
0.51
0.51
0.51
0.72
0.72
0.83
0.83
0.83
0.83
46
46
46
55
60
60
68
68
68
46
46
46
55
55
55
60
68
68
70
70
70
46
55
55
55
50
50
68
70
72
72
72
72
46
55
55
50
50
68
70
72
72
55
50
60
60
60
60
72
72
80
80
80
80
Output Speed
at 50 Hz
1) Current at max. torque. We recommend to select switch gear and cables suitable for those values.
Power
Factor
Cos o
32

Related product manuals