Technical data for blinker transmitter
10
7
startsMechanical lifetime
Silver plated contacts:
10 V AC/DCU min.
250 V AC/DCU max.
3 A at 250 V (resistive load)
2 A at 250 V (inductive load, cos phi 0.8)
I max. AC current
0.25 A at 250 V (resistive load)I max. DC current
Technical data for handwheel activation switches
10
6
startsMechanical lifetime
Silver plated contacts:
12 V DCU min.
250 V ACU max.
3 A at 250 V (inductive load, cos phi = 0.8)I max. AC current
3 A at 12 V (resistive load)I max. DC current
13.2. Technical data Actuator controls
Features and functions
Refer to name plateExplosion protection
Refer to name plates at actuator controls and motor
Permissible variation of mains voltage: ±10 %
Permissible variation of mains voltage: ±30 % (option)
Permissible variation of mains frequency: ±5 %
Power supply
24 V DC: +20 %/15 %,
Current consumption: Basic version approx. 250 mA, with options up to 500 mA
External power supply must have reinforced insulation against mains voltage in accordance with IEC
61010-1 and may only be supplied by a circuit limited to 150 VA in accordance with IEC 61010-1.
External supply of the electronics
(option)
Current consumption of controls depending on mains voltage:
For permissible variation of mains voltage of ±10 %:
100 to 120 V AC = max. 740 mA
208 to 240 V AC = max. 400 mA
380 to 500 V AC = max. 250 mA
515 to 690 V AC = max. 200 mA
For permissible variation of mains voltage of ±30 %:
100 to 120 V AC = max. 1,200 mA
208 to 240 V AC = max. 750 mA
380 to 500 V AC = max. 400 mA
515 to 690 V AC = max. 400 mA
Current consumption
Category III according to IEC 60364-4-443Overvoltage category
The actuator controls are designed for the nominal motor power, refer to motor name plateRated power
Reversing contactors (mechanically and electrically interlocked) for AUMA power classes
A1/A2
Standard:Switchgear
Reversing contactors (mechanically and electrically interlocked) for AUMA power class
A3
Options:
Thyristor unit for mains voltage up to 500 V AC (recommended for modulating actuators)
for AUMA power classes B1, B2 and B3
The reversing contactors are designed for a lifetime of 2 million starts. For applications requiring a high
number of starts, we recommend the use of thyristor units.
For the assignment of AUMA power classes, please refer to electrical data on actuator.
6 digital inputs: OPEN, STOP, CLOSE, EMERGENCY (via opto-isolator, thereof OPEN, STOP, CLOSE
with one common and EMERGENCY without common, respect minimum pulse duration for modulating
actuators).
Control
87
SQEx 05.2 SQEx 14.2 / SQREx 05.2 SQREx 14.2 Control unit - electromechanical
ACExC 01.2 Intrusive Technical data

Table of Contents

Other manuals for AUMA SQEx 05.2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SQEx 05.2 and is the answer not in the manual?

AUMA SQEx 05.2 Specifications

General IconGeneral
BrandAUMA
ModelSQEx 05.2
CategoryController
LanguageEnglish

Related product manuals