2322
The operation of temperature regulation in the receiver is based on the
binary algorithm (on/off) using one or two sensor elements.
The AURATON 2030 RTH regulator allows for setting and/or monitoring
the temperature.
The AURATON T-2 thermometer provides information about the current
temperature only, without the capability of changing it manually.
A) The manual setpoint pairing the AURATON 2030 RTH regulator with the
RTH receiver allows for setting the temperature manually and controlling
it in the location of the fastening of the 2030 RTH regulator.
Cooperation of the AURATON RTH receiver with the
AURATON 2030 RTH regulator and/or the AURATON T-2 thermometer
Cooperation of the RTH
receiver with a heating device
heating device
AURATON RTH
A simplified schematic
of connecting the AURATON RTH
receiver with the heating device
AURATON
2030 RTH
Wireless
temperature regulator
Basic configuration of devices
AURATON T-2
Wireless thermometer
(sold separately)
AURATON H-1
Window handle
(sold separately)
AURATON RTH
Receiver connected
to the heating device
Additional system devices
B) The remote setpoint if the T-2 thermometer is additionally paired with
the RTH receiver, the AURATON 2030 RTH regulator retains the capability
of temperature setting, however its control is performed with the paired
T-2 thermometer only. This feature allows for regulating the temperature
in a room other than the one where the AURATON 2030 RTH regulator
is placed.
An example: you want the temperature in the children’s room” to be
always at 22°C, however you do not want children to be able
to change it - in that room, you install the T-2 thermometer, and the
AURATON 2030 RTH regulator in e.g. the kitchen. This way the
temperature in the children’s room” will always be at 22°C regardless
of temperature fluctuations in the kitchen.
C) The factory setpoint (20°C) if the T-2 thermometer is the only device
paired with the RTH receiver, it is not possible to set the temperature
manually, and the RTH receiver maintains the factory temperature
setpoint of 20°C.
NOTE!
1. The sequence of pairing the AURATON 2030 RTH regulator and the T-2
thermometer is very important. If you want to maintain the remote
setpoint, you must first pair the AURATON 2030 RTH with the RTH
receiver, and then the T-2 thermometer. Reversing the pairing sequence
will cause automatic deregistering of the previously paired T-2
thermometer and entering the mode of operation described in item A.
2. The RTH receiver can operate with one AURATON 2030 RTH regulator
and/or one T-2 thermometer only. Pairing a new regulator causes
deregistering the previously paired regulator and the T-2 thermometer.
Pairing a new T-2 thermometer causes deregistering the previously
paired T-2 thermometer only.
3. The 2030 RTH regulator and/or the T-2 thermometer can operate with
an unlimited number of receivers, e.g. one regulator can control
simultaneously two independent heating devices.
4. When the AURATON 2030 RTH operates with the T-2 thermometer,
the operating status indicator on the display of the 2030 RTH regulator
does not reflect the operating status of the heating device.