Technical specifications
Working temperature range
Temperature measurement range: 5 30°C
Span: ±0,2°C / ±0,4°C / PWM
Accuracy of temperature ±1°C
measurement:
Temperature levels: 8 + 3
Number of programs: 8 for week days,
8 for Saturday, 8 for Sunday
Anti-freezing temperature: 4 10°C
Working cycles: weekly, programmable
5 week days + Saturday + Sunday
Working mode control: LED (the RTH receiver) / LCD (the regulator)
Maximum load: AURATON 2030 ~ 8A 250VAC (inductive 5A)
AURATON RTH ~ 16A 250VAC
Power supply AURATON 2030
2x AA alkaline battery
AURATON 2030 RTH
RTH power supply: 230VAC, 50Hz
RTH radio frequency: 868MHz
RTH Operation range: in a typical building, with standard construction
of walls - approx. 30 m
an open space - up to 300 m
: 0 35°C
Disposing of the devices
The devices are marked with the crossed waste bin symbol. According
to European Directive no. 2002/96/EU and the Act concerning used
up electric and electronic equipment, such a marking indicates that
this equipment may not be placed with other household generated waste.
The user is responsible for delivering the devices to a reception point
for used-up electric and electronic equipment.
2928
The AURATON RTH receiver connection schematics
AURATON 2030 RTH
AURATON RTH
OFF
ON
IN
OUT
ALARM
RESET
230 VAC
~
L N
230 V
~
AURATON 2030 RTH
AURATON RTH
OFF
ON
IN
OUT
ALARM
RESET
230 VAC
~
L N
L
N
L
N
Max. 230V
~
16 A
Max. 230V
~
WARNING !
Cables supplied with the regulator are designed for conducting
maximal load of 2.5 A.
If devices to be connected require more power, the cables need
to be replaced with cables of the appropriate cross-sectional area.
!
heating
device
e.g. a gas furnace
electric
heating
device
AURATON 2030 RTH