AUTEC - Air series
Light signals 9
LILK1E00-01
The red LED [A]… Meaning
…is o. The transmitting unit works correctly.
… is steady on during start up. The STOP pushbutton is pressed or damaged.
... blinks twice per second during
start up.
At least one of the commands that were checked at start-
up is enabled or damaged (see technical data sheet).
... blinks three times per second
during start up.
Thebatteryisat.
... is steady on for 2s. The transmitting unit does not work correctly.
… blinks slowly (one blink per
second).
The battery has less than 1h run time.
... blinks fast. The battery has a 10min run time.
LEDs … Meaning
… the green [B] and red [A] LEDs
are steady on during start up.
A wrong "Key ID 0-1" or "ID internal tx memory" has been
inserted in the transmitting unit, or this is a "BACK-UP
UNIT".
…the green [B] and red [A] LEDs
blink 3 times per second during
start up.
The "Key ID 0-1" or the "ID internal tx memory" is
damaged.
... the green [B] and red [A] LEDs
blink alternately.
30 s left before the transmitting unit automatically switches
o.
The green LED [B] blinks and the
red LED [A] is steady during start
up.
The procedure corresponding to the UNPAIR submenu
has been carried out.
See paragraph 6.3 to check the meaning of LEDs for Data Feedback function [C].