EasyManuals Logo

AUTOHELM ST50 PLUS User Manual

AUTOHELM ST50 PLUS
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
1-6
ST50 PLUS RADAR Operation and
fnstallation
Handbook
1.4 Specifications
1.4.1 General
1)
Maximum range:
16 nautical miles
2) Minimum range:
Less than 35 m (25 yds) on the
.125 nm range.
3) Range Scales:
Range Number of
Range ring
rings
interval
0.125 nm 2 0.0625 nm
0.25 nm 2
0.125 nm
0.5 nm 2
0.25 nm
0.75 nm 3 0.25 nm
1.0 nm 4 0.25 nm
1.5 nm 6 0.25 nm
3 nm 6
0.5 nm
6 nm 6 1 nm
12 nm 6 2 nm
16 nm 4
4 nm
4) Range discrimination: Less than 35 yds.
5) Range ring accuracy: Better than
f
1.5% of maximum range of
the scale in use, or 22 m, whichever is
the greater.
6) Bearing accuracy: + 1 degree.
7) Display device
LCD: Diagonal 168 mm (6.6’)
Effective display area 134.4 x 100.8
;n5fl
x
3.9’)
8) Environmental conditions:
Radome:
Temperature
-15-C
to +55-C
Humidity Up to 95% at 35-C
Display Units:
Temperature -10-C to +55’C (EXCEPT
LCD)
Temperature O’C to +40-C
(LCD)
Humidity Up to 95% at 35-C
9)
Input power requirements: 10.2
m
16V dc
10) Power Consumption: 30 W
Note: LCD performance will be slightly deteriorated in response
speed and brightness during extreme low temperatures.
Section
1.
Introduction
1.42 Display Unit
1)
2)
3)
4)
5)
6)
7)
Dimensions:
Mounting:
Weight:
LCD:
Width 208 mm (8.2’)
Depth 68 mm (2.7’)
Height 198 mm (7.8’)
without bracket
Table, bulkhead, overhead or flush
mounting
Approx. 1.8 kg (Approx. 4
Ibs)
7’ equivalent display area (6.61’
diagonal)
Contrast: Auto temperature, sensing
compensation
Video
4 levels quantitized.
Display Resolution:
320 x 240 pixels
Bearing synchronizing system: Motor Encoder
8) Tuning:
9) Bearing scale:
10)
Ship’s heading marker:
11)
VRM:
12) EBL:
13) EBL Resolution:
14) Alarm:
15) Off Center
16) Zoom
17) Timed TX
Auto/Manual
360’ scale graduated at intervals of 10’
Electrical
Digital readout on LCD in the range of
0.00 to 16.0 nm, 3 digit
Digital-On-
Screen-Display
Digital readout on LCD in the bearing of
0’ to
360’,
3 digit Digital-On-Screen
Display
1’
Audible alarm and zone mark on PPI
Up to 66% radius (all ranges, except 16
nm range scale)
X2 enlargement any range except
l/8
nm scale.
Rotation Period Select 10, 20 or 30
Scans
Repetition Period Select 3, 5, 10 or 15
Minutes

Other manuals for AUTOHELM ST50 PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUTOHELM ST50 PLUS and is the answer not in the manual?

AUTOHELM ST50 PLUS Specifications

General IconGeneral
BrandAUTOHELM
ModelST50 PLUS
CategoryTransducer
LanguageEnglish