7 Counter Mode     
50    © Copyright Reserved Autonics Co., Ltd. 
 
Output 
mode 
Up/Down A, B, C 
S [S] 
 
※OUT1 and OUT2 keep ON status in following condition: 
Counting display value 
 PRESET1 
Counting display value 
 PRESET2 
T [T] 
 
※OUT1 output is off: Counting display value 
 PRESET1   
(when PRESET 1 is 0, OUT1 output maintains ON state.) 
※
OUT2 keeps ON status in following condition: 
Counting display value 
 PRESET2 
D [
D
] 
 
※When counting display value is equal to setting value [PRESET1, PRESET2) 
only, OUT1 or OUT2 output keeps ON status. 
※When setting 1kcps for counting speed, solid state contact output should   
be used. 
(When using contact output, it is difficult to execute normal output operation due 
to contact reaction time.)
 
 
※OUT output as 1-stage setting value change model operates as output of OUT 2 as 2-stage 
 
  setting value change model.   
※In case of 2-stage setting value change model, OUT1 output operates as as one-shot output or 
 
  retained output. (except  S, T, D mode) 
※OUT1 output is available to set as ‘0’ at every output mode. The output for ‘0’ setting executes.   
※In case of C[C], R[R], P[P], Q[Q] output mode, OUT2 output is not available to set as ‘0’.