7 Counter Mode 
© Copyright Reserved Autonics Co., Ltd.    51 
7.4  Counter operation for indicator model 
※Only for indicator model. 
Indication 
mode 
[
] 
Up input mode   
(Up, Up-1, Up-2) 
(Down, Down-1, Down-2) 
TOTAL 
[TOTAL] 
 
 
Count value increases or decreases until RESET input is applied. 
When input is over max./min. counting value, it displays 0. When Reset input is applied, 
it displays 0(Up)/999999(Down). 
HOLD 
[HOLD] 
 
 
Count value increases or decreases  until RESET input is applied. When input  is 
reaching  setting value(Up)/0(Down),  the display value is hold. When Reset 
applied, it displays 0(Up)/setting value(Down). 
   
※When the command input [UD-A], individual input [UD-B], phase difference input [UD-C] mode, 
 
※In case of UP/DOWN [UD-A, UD-B, UD-C] input mode, indication mode [DSpM] parameter 
 
  does not appear.