5 Counter mode
© Copyright Reserved Autonics Co., Ltd. 49
Input
mode
Counting chart
Down
[DN]
When INA is counting input, INB is no counting input.
When INB is counting input, INA is no counting input.
Down-1
[DN-1]
When INA input signal is rising ( ) , it counts.
INA: Counting input
INB: No counting input
Down-2
[
DN-2]
When INA input signal is falling ( ) , it counts.
INA: Counting input
INB: No counting input
Down-3
[
DN-3]
When INA or INB input signal is rising ( ) , it counts.
INA: Counting input
INB: Counting input