EasyManua.ls Logo

Autonics CX6M-1P Series - Page 50

Autonics CX6M-1P Series
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Counter mode
50 © Copyright Reserved Autonics Co., Ltd.
Input
mode
Counting chart
Up/
Down-A
[UD-A]
INA: Counting input
INB: Counting command input
When INB is "L", counting command is up.
When INB is "H", counting command is down.
Up/
Down-B
1
[UD-B]
INA: Up counting input
INB: Down counting input
When INA and INB input signals are rising ( ) at the same time, it maintains
previous value.
Up/
Down-C
1
[UD-C]
When connecting encoder output A, B phase with counter input, INA, INB, set input
mode [InM] as phase different input [UD-C] for counter operation.
1: This is for the voltage input(PNP)/no-voltage input(NPN) selectable model (CX6-□□).
: over min. signal width, : over than 1/2 of min. signal width. If the signal is smaller than
these width, it may cause counting error (±1).