5 Counter mode
© Copyright Reserved Autonics Co., Ltd. 51
The meaning of “H”, “L”
Input method
Character
Voltage input
(PNP)
No-voltage input
(NPN)
H 5-30VDC Short
L 0-2VDC Open
Min. signal width by counting speed (1cps=1Hz)
CX6-□□
Counting speed
Min. signal width
1cps 500ms
30cps 16.7ms
300cps 1.67ms
1kcps 0.5ms
5kcps 0.1ms
CX6-□□F
Counting speed
Min. signal width
20cps 25ms