6 Timer mode     
68    © Copyright Reserved Autonics Co., Ltd. 
 
Time chart 
OND.2 
[ONd2] 
Power ON Delay 2 (Power Hold) 
 
1)Power ON Time Start (there is no INA function) 
2)RESET ON: Time RESET   
 
  RESET ON→OFF: Time Start 
3)Control output operates as retained (Hold) or one-shot 
  output.   
4)It memorizes display value at the moment of power 
 
  OF F.  
 
OND.3 
[ONd3] 
Signal ON Delay 3 (Power HOLD/RESET) 
1)Power ON Time Start (there is no INA function) 
2)RESET ON: Time RESET 
 
  RESET ON→OFF: Time Start 
3)Control output operates as retained (Hold) or   
one-shot output. 
4)If time reached setting time at the moment of power   
ON, it is automatically reset. 
 
 
※Power RESET: There is no memory protection. (resets the display value when power is off) 
※Power Hold: There is memory protection. (memorizes the display value at the moment of 
    power off, indicates the memorized display value when power is resupplied.)