Default
Alarm output1 Operation 
AL-1 DVCC
Alarm output1 Option AL!T AL-A
 A!HY 001
Alarm output1 contact 
A!N NO
time
A!ON 0000
time
A!OF 0000
Alarm output2 Operation 
AL-2 ]]DV
Alarm output2 Option AL@T AL-A
 A@HY 001
Alarm output2 contact 
A@N NO
time
A@ON 0000
time
A@OF 0000
AL-3 OFF
 AL#T AL-A
 A#HY 001
A#N NO
time
A#ON 0000
time
A#OF 0000
LBA time LBaT 0000
 LBaB
 002 
003
Analog Transmission 
AoM1    PV
Transmission output1 
FsL1  -200
Transmission output1 
high limit
FsH1  1350
Analog Transmission 
AoM2   PV
Transmission output2 
FsL2 -200
Transmission output2 
high limit
FsH2 1350
 ADRS   01
 BPS 96
 PRTY NONE
 STP 2
Response time RSWT 20
 COMW EnA
  
  Default
Multi SV  MtSV 1
 DI-K STOP
Digital input1 Terminal 
DI-1   OFF
Digital input2 Terminal 
DI-2   OFF
 ItMV AUTO
MV
PrMV 00)0
Sensor error MV ErMV 00)0
Control stop MV StMV 00)0
Control stop alarm 
output
StAL CONT
User level USER STND
SV setting lock LcSV OFF
Parameter 1 group lock LcP1 OFF
Parameter 2 group lock LcP2 OFF
 LcP3 OFF
Parameter 4 group lock LcP4 OFF
Parameter 5 group lock LcPS OFF
 PWD 0000
  
  Default
Control output 
R-S RUN
Multi SV selection SV-N SV-0
Heater current 
monitoring
CT-A  )0
 AL!L 1550
Alarm output1 high limit AL!H 1550
 AL@L 1550
Alarm output2 high limit AL@H 1550
 AL#L 1550
 AL#H 1550
Multi SV 0 SV-0 0000
Multi SV 1 SV-1 0000
Multi SV 2 SV-2 0000
Multi SV-3 0000
  
  Default
 AT OFF
Heating proportional 
H-P 01)0
Cooling proportional 
C-P 01)0
Heating integral time H-1 0000
Cooling integral time C-1 0000
 H-D 0000
 C-D 0000
 DB 0000
Manual reset REST 05)0
 hHYS 002
 hOST 000
 cHYS 002
 cOST 000
 L-MV `0)0
MV high limit H-MV 10)0
RAMP up change rate RAMU 000
 RAMD 000
RAMP time unit rUNT MIN
  
  Default
 IN-T KCaH
Temperature unit UNIT ><?C
 L-RG 0)00
Analog high limit H-RG 1)00
 DOT )0
 L-SC 00)0
High limit scale H-SC 10)0
 dUNT >?/O
Input correction IN-B 0000
 MAvF 00)1
 L-SV -200
SV high limit H-SV 1350
 O-FT
HEAT
 H-C
 
Cooling 
 C-MD
 PID
  pP
 
Cooling-
 AtT TUN1
OUT1 control output 
selection
OUT1 CURR
O!SR STND
OUT1 current output 
range
O!MA 4-20
OUT2 control output 
selection
OUT2 CURR
OUT2 current output 
range
O@MA 4-20
 H-T
02)0 
00@0 
 C-T
• 
• 
• 
88* 8
Alarm 
Alarm 
  
• 
Name  
  No alarm output
Deviation 
high limit
SV         
100
PV
110
 ON
PV
SV
100
 ON
SV as high-limit is higher 
 
Deviation 
PV
SV
100
ON 
SV
100
PV
110
ON 
 
Deviation 
limit
PV
PV
110
SV
100
ON ON 
Deviation 
limit reverse
PV
PV
110
SV
100
 ON 
value high 
limit 
PV
SV
100
 ON
SV
100
PV
110
 ON
 
limit
PV
SV
100
ON 
SV
100
PV
110
ON 
 
 
 
 
  
Name 
Condition 
alarm
-
Alarm latch 
-
Alarm 
 
 
change 
alarm 
temperature 
or  change 
STOP to RUN 
Alarm