2 Modbus Mapping Table
© Copyright Reserved Autonics Co., Ltd. 35
2.5.8 Digital iput setting group (Func: 03/06/16, RW: R/W)
No(Address)
Parameter
Description
Setting range
Unit
Factory
default
TM2
TM4
40
0573(024C)
-
Digital Input 1 Func
Digital input terminal 1
function
0: OFF 1: STOP
2: AL
-
RESET 3: MANUAL
4: MULTI
-SV
-
0
40
0574(024D)
-
Digital Input 2 Func
Digital input terminal 2
function
0: OFF 1: STOP
2: AL
-
RESET 3: MANUAL
4: MULTI
-SV
-
0
40
0575(024E)
-
Digital Input 1
Ch
Digital input terminal 1
target channel
0: CH1 1: CH2
-
0
40
0576(024F)
-
Digital Input 2
Ch
Digital input terminal 2
target channel
0: CH1 1: CH2
-
1
40
0577(0250)
to
40
0600(0257)
-
Reserved