Dual PID Auto Tuning Control
Parameter 2 group
Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default
IN-T KCaH AL-T AL-A PIDT PIdS H-SC 1300
EU-1 AL-1 AtT TVN1 O-FT HEAT L-SC -100
EU-2 AL-2 RAMP OFF UNIT ?C LOC OFF
※
Press
( ) key and the right digit of SV display part ashes. Press ( ) or ( ) key and move to the desired digit.
Press
( ), ( ) keys to change SV and press
MD
key to complete the set. Press
MD
key again and it moves to next parameter.
※
After completing setting at each parameter, press
MD
key for 3 sec. and it returns to RUN mode.
※
If no key touched for 60sec., it will return to RUN mode automatically.
※
1: It may not be displayed by input type switch
.
※
2: This is displayed only for model with High/Low-limit of transmission output.
Factory defaults(Parameter 2 group)
IN-T
Input type: Select from 19 type
L-SC
Set scaling low limit (include analog output)
EU-1
Event 1: Select from 9 type
DOT
Select decimal point position for Analog input
EU-2
Event 2: Select from 9 type
FS-H
Set the high-limit when retransmission output is applied. (20mA)
AL-T
Alarm type: Select from 4 type
FS-L
Set the low-limit when retransmission output is applied. (4mA)
AtT
Auto-tuning: Selectable
TUN1
or
TUN2
.
RAMP
Able to set ON and OFF of Ramp function.
PIDT
PID: Selectable
PIDF
or
PIDS
.
BPS
Set communication speed
O-FT
Selectable heat-function or cool-function
ADRS
Set communication address(01 to 99)
UNIT
Temperature unit:
℃
or
℉
LOC
The data cannot be changed when the lock key is ON
H-SC
Set scaling high limit (include analog output)
If pressing
MD
+ key for 3sec. at once in RUN state, it will go to parameter 2 group.
Input type
Event 1
mode Alarm type PID type
Control
operating
type
Temperature
unit
※
2
※
2
Input type Lock
※
2
Event 2
mode
Auto-tuning
type
Scaling
high limit
Transmission
output
low limit
Communication
address
Communication
speed
Ramp
function
Transmission
output
high limit
Scaling
low limit
※
1
Decimal
point
※
1
IN-T
KCaH
JIcH
JIcL
R PR
ECrL
ECrH
TCcH
TCcL
S PR
NN
U TT
JPtH
KCaL
JPtL
DPtH
DPtL
A--1
A--2
A--3
EU-1
LBA
SBA
AL-0
AL-1
AL-2
AL-4
AL-3
AL-5
AL-6
EU-2
LBA
SBA
AL-0
AL-1
AL-2
AL-4
AL-3
AL-5
AL-6
AL-T
AL-A
AL-B
AL-C
AL-D
IN-T
AtT
TVN1
TVN2
LOC
OFF
ON
PIDT
PIdS
PIdF
ADRS
01
O-FT
HEAT
COOL
BPS
2400
4800
9600
UNIT
?C
?F
H-SC
1300
RAMP
OFF
ON
L-SC
-100
FS-L
-100
FS-H
1300
DOT
0
)0
)00
)000
MD
MD MD MD MD MD MD MD MD MD MD
MD MD MD MD MD
MD
Run mode
MD
+ 3sec.