- 4 -
-
2Connect the machine to power supply and turn it on.
3Put the cleaning frame on the ultrasonic groove, and put the injector
into the whole ofthe frame.
3.1.2 Steps
01 Ultrasonic Cleaning
1
Pour proper quantity cleaning fluid into ultrasonic groove.
2Connect the actuation cable to the injector needed to be cleaned.
3 Press Left or Right Arrow key to select Ultrasonic Cleaning from
panel, then press RUNkey.
4Press Left or Right Arrowkey to set up working timedefault time is 10
minutes.
5
Press RUNkey. (You can press PAUSE or STOP at any time during the
operation process.)
6After the cleaning is completed, it will stop automatically.
7
Take the injector out ofthe ultrasonic groove.
NOTE
1. During the cleaning, get the injector close to ear, listen carefully, you
may hear the intermittent sound ofclosing and opening of the
injectors valve, otherwise the injectors valve is blocked.
2. Please do not turn on the ultrasonic trough when there is not clean
fluid in the trough, otherwise the machine will be damaged.
3.2 Injector Test
This function is to testthe condition of atomization, drop, block, spray
angle,and uniformity ofthe injector.

Questions and Answers: