EasyManuals Logo

Autool CT-200 User Manual

Autool CT-200
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
-
- 9 -
-
2)Press Left or Right Arrow key to set up injecting time (account time)
3)The next steps are the same as what listed in 02 Idle Speed Test.
NOTE
To simulate the injecting condition after working for a certain times in Idle
speed
09 Medium Speed Spray Value Test
1)Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2)The next steps are the same as what listed in 08 Idling Spray Value Test.
10 High Speed Spray Value Test
1)Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2)The next steps are the same as what listed in 08 Idling Spray Value Test.
NOTE
1. Check the deviation of the spray value: test the spray value in different
rpm, checkthe spray value in different measuring cylinder, the
deviation should not exceed 2% or refer the specification of the injector.
2. Leakage test: leakage should not occur within 1 minute under 0.3MPA
system pressure.
3.3 Reverse Flushing
The flush fluid go into the injector through its outlet and go out through
its inlet, so that it can clean the filth inside, which can not be cleaned by
normal way.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autool CT-200 and is the answer not in the manual?

Autool CT-200 Specifications

General IconGeneral
BrandAutool
ModelCT-200
CategoryService Equipment
LanguageEnglish

Related product manuals