- 7 -
-
key.
3)Press Left or Right Arrow key to set up working time. (Normally, it is 2
minutes.)
4)Press RUN key.
5)Turn Pressure Adjusting Knob until the pressure is 0.25-0.3MPa..
6)Press Left or Right Arrow key to select properinjection pulse (default
value is 3MS).
7)When the working time is zero, the machine will stop.
8)Release the fluid into the pump after test is completed.
03 Medium Speed Test
1)Press Left or Right Arrow key to select Medium Speed Test.
2)Press RUN key.
3)The next steps are the same as what listed in 02 Idle Speed Test.
04 High Speed Test
1)Press Left or Right Arrow key to select High Speed Test.
2)Press RUN key.
3The next steps are the same as what listed in 02 Idle Speed Test.
05 Accelerating Test
1)Press Left or Right Arrow key to select Accelerating Test.
2)Press RUN key.
3
The next steps are the same as what listed in 02 Idle Speed Test.
NOTE
1. System pressure, working time and pulse width are set up
automatically by system itself. (Default working time cycle is 10