Page - 9
Cell Output Control
The ChlorSync
®
display will show the selected sanitizer output % and cell polarity during normal
operation. The or buttons are used to adjust the sanitizer output % to the desired level.
When paired with the PoolSync
TM
option, consult the PoolSync
TM
app for more information.
To increase or decrease sanitizer output %:
1.
Press the button one time to decrease sanitizer output by 1%, or the button one time to
increase output by 1%. Press and hold for 10% increments or decrements.
2.
The current sanitizer output will begin to flash on the display. The sanitizer output can be adjusted at
this time.
3.
Release the orbutton when the desired sanitizer output is reached. The unit will resume
normal operation.
The rotating character shown on the left side of the display informs that the unit is generating
chlorine. If the rotating character is not present, the cell is not generating chlorine at that time but
will do so shortly.
l A clockwise motion denotes forward polarity on the blades and a counter-clockwise denotes reverse
polarity.
Rotating character shown clock-wise
Figure 5
Boost Mode On/Off
The Boost feature is used to increase the sanitizer output from its normal setting to 100% for a
cumulative 24 hour period of circulation pump run time. During this time, the sanitizer output
display will show "100%" as well as the hours remaining in the boost period. When the boost
period expires or is manually terminated, the sanitizer output % returns to its previous setting
and normal operation.
l
Press the orbuttons simultaneously to turn Boost Mode on or off.
WATER BALANCE AND CHEMISTRY RECOMMENDATIONS
Water balance is the relationship between different chemical measurements in your pool water.
A pool that is balanced has proper levels of pH, Total Alkalinity and Calcium Hardness.
Balanced water can also be defined as water that is not corrosive or scaling. Water that is not
balanced can damage equipment and pool surfaces.
Proper water chemistry levels are essential to maintain safe and consistent swimming pool
operation. Sanitizers are used to destroy harmful or otherwise objectionable organisms.
Stabilizer or Cyanuric Acid (CYA) is used in many regions to reduce unnecessary loss of
chlorine to sunlight. Salt is used by the ChlorSync
®
to generate chlorine sanitizer.
Please note the following recommended water chemistry parameters are for residential pool/spa
applications only. Follow local regulatory guidelines for any commercial pool applications.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autopilot ChlorSync CS50 and is the answer not in the manual?

Autopilot ChlorSync CS50 Specifications

General IconGeneral
BrandAutopilot
ModelChlorSync CS50
CategoryLighting Equipment
LanguageEnglish

Related product manuals