6.
Fill the rest of the cell with muriatic acid, being careful not to allow solution to overflow onto the
outside of the cell. This allows for an approximate 1-to-4 solution. Always add the acid to the water.
If you do it the other way around, it may cause the solution to spray back, causing serious injury.
l If solution does spill over onto the outside of the cell, rinse with water immediately.
l Sulfuric and no fume acid do not give favorable results and are not recommended.
7.
Allow the solution to sit in the cell for fifteen (15) minutes or until the acid stops bubbling.
8.
Safely dispose of the solution; pouring it into the pool is recommended.
9.
Remove the cell from the stand and rinse with light water pressure; re-inspect the cell, and repeat
acid cleaning if the cell is still scaled.
10.
When the cleaning process is complete, re-connect the cell to the plumbing and re-power the unit.
Check for leaks and proper operation.
Winterizing
CAUTION - Failure to heed the following may result in equipment damage.
l Special measures are required in the event of freezing conditions. The ChlorSync
®
may be damaged if
measures are not taken in advance of freezing conditions. Equipment damage due to freezing
conditions is NOT covered under the equipment warranty.
During brief freezing conditions, allow the filtration system to run continuously throughout the
freeze period. Circulating (moving) water will not freeze. In areas where freezing conditions are
prevalent and sustained, the equipment must be winterized as follows:
l Drain water from pump, filter, and all intake and return lines.
l Remove the cell, clean thoroughly and store. Cover open pipe ends once cell is removed to prevent
intrusion from debris and small animals.
Spring Start Up
It is recommended the water be manually chlorine-shocked when first starting up the pool in the
springtime. Test water and add the appropriate chemicals to balance the pool water as per the
levels recommended in this manual. See "Water Balance and Chemistry Recommendations" on
page 9. Be sure to check salt and Cyanuric acid (stabilizer), bringing those readings up to the
recommended levels. Inspect the cell and test the flow sensor; clean and/or replace those items
as necessary.
Fuse Replacement
WARNING - Failure to heed the following may result in permanent injury or death.
l ELECTRICAL SHOCK HAZARD Turn off the electrical power to unit before servicing.
Fuse Location
Figure 7
To inspect or replace the fuse, disconnect power
and remove power center cover. See Figure 7 for
location of the fuse.
Replace with a standard auto, 10 amp mini blade
fuse that is available at most automotive supply
stores.
10 Amp
Mini Blade
Fuse

Questions and Answers: