7.4 Review of Installer Menu Programming
7.4.a Calibrate Temperature
You must wait a full two minutes after start up to calibrate temperature. Used only when it is
desired to match the display of the Pool Pilot
®
to another on-site thermometer.
1.
Press MENU/ENTER, press ▽ until “Installer menu” is displayed and press MENU/ENTER.
2.
Press ▽ until “Calibrate temp.” is displayed and press MENU/ENTER.
3.
Press △ or▽ until the desired temperature is shown, then press MENU/ENTER. The maximum
adjustment is ± 6 °F (± 3 °C).
4.
Press △ or▽ until "Exit Menu Mode" is displayed and press MENU/ENTER.
7.4.b Calibrate Salt
The unit has been calibrated at the factory and should not require further adjustments. In the
event the salt display does not match on-site test results, follow these steps (it is necessary to
wait 2 minutes after water flow has started before calibrating salt):
1.
Press MENU/ENTER, press ▽ until “Installer Menu” is displayed and press MENU/ENTER.
2.
Press ▽ until “Calibrate salt” is displayed and press MENU/ENTER.
3.
Press △ or▽ until the number on the display matches the accurately measured pool sample, press
MENU/ENTER. The maximum adjustment is ± 1,000 ppm (mg/L).
4.
Press △ or▽ until "Exit Menu Mode" is displayed and press MENU/ENTER.
7.4.c Set Pool Volume
The pool volume must be programmed for the “Add salt ### lb (kg)” display to be accurate. See
"Calculating Pool Volume" on page 25.
1.
Press MENU/ENTER, press ▽ until “Installer menu” is displayed.
2.
Press ▽ until “Set pool volume” is displayed, press the MENU/ENTER.
3.
Factory setting is 000 gallons (000 Liters). The range is 000 to 1,000,000 gallons (000 to 4,000,000
Liters).
4.
Press △ or▽ until correct pool size is displayed, press MENU/ENTER.
5.
Press △ or▽ until "Exit Menu Mode" is displayed and press MENU/ENTER.