Autostacker™ Parking Lift 25 P/N 5900248 — Rev. B — May 2021
To connect the Hydraulic Hoses:
1. Locate the two Hydraulic Hoses that come with your Lift.
The two Hydraulic Hoses are the same length; it does not matter which Hydraulic Hose goes to
which Hydraulic Cylinder on the Lift.
2. Starting near the Console, route both Hydraulic Hoses through the Bottom Connector Tube and
pull it out at the Hydraulic Cylinder that is furthest away from the Console.
One Hydraulic Hose goes to the Hydraulic Cylinder that is closest to the Console, while the other
Hydraulic Hose goes to the Hydraulic Cylinder that is furthest away from the Console.
Leave enough of the Hydraulic Hose on the Console end to allow the Hydraulic Hoses to be
connected to the Power Unit up through one of the openings at the bottom of the Console.
Pull out enough of the Hydraulic Hose to reach the Bulkhead Fittings when it is time to put all of the
components together.
3. On each Hydraulic Cylinder, install Velocity Fuses in the Ports near the bottom of each Hydraulic
Cylinder. Finger tighten the connection.
Use Thread Sealant on NPT Threads only.
Refer to About Velocity Fuses for more information.
4. For both Hydraulic Cylinders, remove one Nut from the Bulkhead Fitting, put the Bulkhead Fitting
into the Connector Weldment, put the Nut you just removed back onto the Bulkhead Fitting, and
finger tighten both Nuts around the Connector Weldment.
5. For both Hydraulic Cylinders, connect the Hydraulic Line Assembly to the top end of the Bulkhead
Fitting and the other end to the top end of the Velocity Fuse. Finger tighten the connections.
6. For both Hydraulic Cylinders, connect the Hydraulic Hose to the bottom end of the Bulkhead
Fitting. Finger tighten the connections.
7. Attach two Elbow Fittings to both Hydraulic Pressure Ports on the Power Unit.
There are two Hydraulic Pressure Ports on a Power Unit, in varying locations (depending on the
Power Unit you have). Refer to Connect the Power Unit to identify your Power Unit layout.
8. Route the two Hydraulic Hoses, one at a time, through an opening along the bottom of the
Console and up to one of the Elbow Fittings, then connect them. It does not matter which
Hydraulic Hose goes to which Hydraulic Pressure Port.
Coil any additional Hydraulic Hose length inside the Console.
9. Once all connections have been made, use the appropriate tools to fully tighten all of the
finger-tightened connections.