FEATURES AND SPECIFICATIONS PAGE 5
Installation Options:
¥ Residential or Mobile Home
¥ Straight or Corner Placement
¥ Bedroom Approved
¥ Alcove Approved
¥ Vertical or Horizontal Vent
¥ Approved for use in homes of
unusually tight construction
Features:
¥ Works During Power Outages (standing pilot)
¥ High Efficiency; 81.5% Natural Gas, 83.3% LP (Steady State)
¥ Optional Thermostat or Remote Control
¥ Realistic "Wood Fire" Look
¥ Convenient Operating Controls
¥ Variable-Rate Heat Output
¥ Quiet Blower for Effective Heat Distribution
¥ Low Maintenance
Heating Specifications:
Natural Gas LP (Propane)
Approximate Heating Capacity (in square feet)* 600 - 1600 600 - 1600
High Burn Input Rate (In BTU's) 31,000 31,000
Low Burn Input Rate (In BTU's) 18,000 17,000
Efficiency** 81.5% 83.3%
AFUE (Annual Fuel Utilization Efficiency) 72.6% 74.2%
* Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.
** Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system.
To measure the net BTU's, multiply the BTU input by the efficiency percentage (81.5% for natural gas, 83.3% for LP).
Dimensions
4-1/2"
20"
24-1/2"
31-1/4"
2-3/4"
Fuel: The stove is designed either for natural gas or for propane. Check
the sticker on the top of the gas control valve.
Emissions: This unit has passed the ANSI emission standards for vented room
stoves as tested by Warnock Hersey, LTD.
Electrical Specifications: 115 Volts, 1.3 Amps, 60 Hz (150 watts on high)