Loading...
Avaya Inc. External Distribution
20
avaya.com
5. IPFIX Configuration Examples for the
ERS 5000 or ERS 4500
5.1 IPFIX Basic Configuration for Ethernet Routing
Switch:
For this configuration example, we will configure the following:
Enable IPFIX collecting on a standalone Ethernet Routing Switch ports 12 and 13
Configure the IPFIX active-time to 30 seconds. This will allow viewing the IPFIX flows
on port 12 for up to 30 seconds.
Add an IPFIX collector which has an IP address of 172.30.30.20. We will leave the
default setting of UDP dst-port 9995.
5.1.1 Configuration
ERS-STACKABLE: Step 1 Enable IPFIX globally
ERS-Stackable(config)# ip ipfix enable
ERS-STACKABLE: Step 2 Enable IPFIX on port 7/26
ERS-Stackable(config)# interface fastEthernet 12,13
ERS-Stackable(config)# ip ipfix enable
ERS-Stackable(config)# exit
ERS-STACKABLE: Step 3 Change the aging timeout to 30 seconds
ERS-Stackable(config)# ip ipfix slot 1 aging-interval 30
ERS-STACKABLE: Step 4 Add the IPFIX Collector
ERS-Stackable(config)# ip ipfix collector 1 172.30.30.20 enable