Unit connectors
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded
cables is recommended.
Power connector - Mini DC connector. 5.1V DC, max 4.0W. See product label for
± connection.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from
a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an
active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo
connector must be used for the audio out.
I/O terminal connector - Used in applications for e.g. motion detection,
event triggering, time lapse recording and alarm notifications. It provides the
interface to:
1 transistor output - For connecting external devices such as relays and LEDs. Connected
devices can be activated by the VAPIX Application Programming Interface (API), by the out-
put buttons on the Live View page or by an Event Type. The output will show as active
(shown under Event Configuration > Port Status) if the alarm device is activated.
1 digital input - An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc.
When a signal is received the state changes and the input becomes active (shown under
Event Configuration > Port Status).
Auxiliary power and GND
Function Pin Notes Specifications
GND 1 Ground
3.3V DC
Power
2 Can be used to power auxiliary equipment.
Note: This pin can only
be used as power out.
Max. load = 50mA
Digital
Input
3 Connect to GND to activate, or leave floating
(or unconnected) to deactivate.
Min. input= - 40V DC
Max. input= + 40V DC
Digital
Output
4 Uses an open-drain NFET transistor with the
source connected to GND. If used with an
external relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
Max. load = 100mA
Max voltage = + 40V DC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis Fixed Dome Network Camera AXIS P3301 and is the answer not in the manual?

Axis Fixed Dome Network Camera AXIS P3301 Specifications

General IconGeneral
BrandAxis
ModelFixed Dome Network Camera AXIS P3301
CategorySecurity Camera
LanguageEnglish

Related product manuals