AXIS M7014/M7010 Installation Guide Page 15
ENGLISH
Unit connectors
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet (PoE) Class 3 - max
12.95W. Using shielded cables is recommended.
Power input connector - 2-pin terminal block used for power input from the
supplied power adapter or an external power supply.
The external power supply alternatives are:
1. The Axis delivered PS-K P/N 34987 (AXIS M7014).
2. The Axis delivered PS-P P/N 42118 (AXIS M7010).
3. An external 8-20 V DC limited power source with a maximum output current of 5A.
RS-485/RS-422 connector - Two 2-pin terminal blocks for RS-485/RS-422 serial interface used
to control auxiliary equipment, e.g. PTZ devices.
The RS-485/RS-422 serial port can be configured to support:
Two-wire RS-485 half duplex
Four-wire RS-485 full duplex
Two-wire RS-422 simplex
Four-wire RS-422 full duplex point to point communication
microSD memory card slot - The microSD memory card can be used for local recording with
removable storage.
BNC connector - Connect a 75 ohm coaxial video cable (max. length 800 feet (250 meters)).
Note:
For each video input 75 Ohm video termination can be enabled/disabled via the product's web page at
Video > Video Input > Video termination. These terminations are enabled on factory default. In cases
Function Pin number Description
GND 1 Ground
DC Power 2 Power input 8-20V DC
max 7W (AXIS M7014)
max 28W (AXIS M7010)
Function Pin Notes
RS-485/RS-422 RX/TX A 1 (RX) For full duplex RS-485/RS-422
(RX/TX) For half duplex RS-485
RS-485/RS-422 RX/TX B 2
RS-485/RS-422 TX A 3 (TX) For full duplex RS-485/RS-422
RS-485/RS-422 TX B 4
1
2
RS-485/422
RX/TX