Output Voltage Regulation
230Vac±5%
Output Frequency
50Hz
Peak Efficiency
93%
Overload Protection
5s@≥130% load; 10s@105%~130% load
Surge Capacity
2 * rated power for 5sec
Nominal DC Voltage
24Vdc 12 Vdc
Cold Start Voltage
23.0Vdc 11.5Vdc
Low DC Warning Voltage
23.0Vdc
22.0Vdc
11.5Vdc
11Vdc
@ load < 50%
@ load ≥ 50%
Low DC Warning Recovery Voltage
23.5Vdc
23.0Vdc
11.7Vdc
11.5Vdc
@ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
21.5Vdc
21.0Vdc
10.7Vdc
10.5Vdc
@ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
30Vdc 15Vdc
High DC Cut-off Voltage
31Vdc 16Vdc
DC Voltage Accuracy +/-0.3%V@ no load
THDV <5% for linear load,<10% for non-linear load @
nominal voltage
DC Offset
≦100mV
No Load Power Consumption
<35W <25W