EasyManua.ls Logo

Badger Meter Blancett B3000 Series - Replacing the Display Board

Badger Meter Blancett B3000 Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Kit Parts Installation
Page 6 June 2018DSY-UM-02582-EN-04
Replacing the Display Board
Service Kit Number B300-106 for the Explosion-Proof display contains:
One explosion-proof display PCB, PN B300024
Five screws, Phillips tri-shank, #4-20 × 1/4, zinc/steel, PN B300113
1� Grasp the enclosure cover and turn it counter-clockwise until it separates from the
enclosure body� Set the cover aside�
2� Remove the TOTAL FLOW RESET key from the display housing by pulling it straight out�
Set it aside�
3.6 VOLTS
+
TADRAN
LITHIUM
INORGANIC
BATTORY
J1
S1
Menu
S4
Enter
S3
Up
S2
Down
COM
1
2
12
1
Thumb Screws
COM
1
2
Total Flow
Reset Key
3� Loosen the two thumb screws and slightly turn the circuit board assembly far enough
to access the battery connector
4� Press the tab on the battery connector plug to release it from the P2 battery
connector socket�
5� Remove the 4 screws holding the CPU board�