15
DISPLAY MANUAL DP C11.UART
ERROR CODE DEFINTION
ERROR CODE DEFINITION
DP C11.UART display can show e-bike faults. When a fault is detected, the icon will be displayed. One of the
following error codes will be displayed.
Error code Error definition Error-shooting method
"07" High voltage protection Check battery voltage
"08" Fault with motor hall sensor inside Check the motor module
"10"
The controller temperature reaches to the top
protection value
Check the controller
"12" Fault with current sensor inside controller Check the controller
"13" Fault with temperature sensor inside battery Check the battery
"21" Fault with wheel speed detecting sensor
Check the installation position
of speed sensor
"22" BMS communication fault Replace the battery
"30" Communication fault Check the controller connection