Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during
filtration. On circ systems, the ozone will run with the circ pump.
The system is factory-programmed with one filter cycle that will run in the
evening (assuming the time-of-day is properly set) when energy rates are often
lower. The filter time and duration are programmable. A second filter cycle can
be enabled as needed.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is
one) will run briefly to purge its plumbing to maintain good water quality.
READY
R
ANGE
FLTR1
JETS
TS
S
J
J
AUX
U
X
A
LIG
H
IGHT
T
H
HEAT
AT
T
JETS AUX LIGHT HEAT
Circulation Pump Modes
If the system is equipped with a circ pump, it may be configured to work in one
of three different ways:
The circ pump operates continuously (24 hours) with the exception of turning t
off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C)
above the set temperature (most likely to happen in very hot climates).
The t circ pump stays on continuously, regardless of water temperature.
A t programmable circ pump will come on when the system is checking
temperature (polling), during filter cycles, during freeze conditions, or when
another pump is on.