Specifications 8-15MN1943
8.3 Motor output
8.3.1 Motor output power (X1) - 1.5 A ~ 16 A models
Unit 1.5 A 3A 6A 10.5 A 16 A
Nominal phase current A
RMS
1.5 3 6 10.5 16
Nominal output power
@ 415 V
kVA 1.08 2.16 4.31 7.55 11.50
Output voltage range (line-line)
@ VDC-bus = 600 V
V
RMS
0 - 430
Output frequency Hz 0 - 2000
Output dV/d t
at drive, phase-phase
at drive, phase-ground
at motor (using 20 m cable), phase-phase
at motor (using 20 m cable), phase-ground
kV/μs
2
1.1
1.9
1.8
Nominal switching frequencies kHz 4.0, 8.0, 16.0
Minimum motor inducta nc e
(per winding)
mH 1
Efficiency % >95
8.3.2 Motor output power (X1) - 21A ~ 33.5 A models
Unit 21 A 26 A 33.5 A
Nominal phase current A
RMS
21 26 33.5
Nominal output power
@ 415 V, 3Φ input
kVA 15.10 18.69 24.08
Output voltage range (line-line)
@ VDC-bus = 600 V
V
RMS
0 - 430
Output frequency Hz 0 - 2000
Output dV/d t
at drive, phase-phase
at drive, phase-ground
at motor (using 20 m cable), phase-phase
at motor (using 20 m cable), phase-ground
kV/μs
2
1.1
1.9
1.8
Nominal switching frequencies kHz 4.0, 8.0, 16.0 *
Minimum motor inducta nc e
(per winding)
mH 1
Efficiency % >95
* 16 kHz not available on 33.5 A model.