www.baldormotion.com
8-32 Specifications MN1943
8.6.4 Digital outputs DOUT0, DOUT1 - status and general purpose (X3)
Unit All models
User supply (maximum) V 28
Output current (max. continuous) mA 100
Fuse
Approximate trip current
Reset time
mA
s
200
<20
Update interval ms 1
8.6.5 Incremental encoder interface (X8)
Unit All models
Encoder interface RS422 A/B Dif ferential, Z index
Maximum input frequency
(quadrature)
MHz 8
Hall inputs RS422 A/B Dif ferential
Output power supply to encoder 5 VDC (±7%), 200 mA max.
Maximum recommended cable length 30.5 m (100 ft)
8.6.6 SSI interface (X8)
Unit All models
SSI encoder interface Differential Data and Clock
Operating mode
(Baldor motors)
Single turn.
Positioning resolution up to 262144
counts/rev (18-bit)
Output power supply to encoder 5 VDC (±7%), 200 mA max.
Maximum recommended cable length 30.5 m (100 ft)
8.6.7 BiSS interface (X8)
Unit All models
BiSS encoder interface Differential Data and Clock
Operating mode Single or multi-turn.
A wide range of devices can be
supported. Contact Baldor technical
support before selecting a device.
Output power supply to encoder 5 VDC (±7%), 200 mA max.