EasyManua.ls Logo

Balluff BNI007Z - Safe State of Outputs 42 Hex; Safe State of the Outputs on Pin 4 42 Hex

Balluff BNI007Z
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Balluff Network Interface / IO-Link BNI IOL-302-002-K006
www.balluff.com
22
5 Configuration: Extended with BNI IOL-302-002-K006
Safe state of
outputs 42hex
The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO-
Link communication is possible or the "valid flag" of the output process data has not been set
by the master, then each output adopts the configured status. The following statuses can be
configured for each pin.
Safe state of
the outputs on
Pin 4 42hex
Byte
0
1
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Sub-
index
4
3
2
1
8
7
6
5
Description
Safe state Port 3 Pin 4
Safe state Port 2 Pin 4
Safe state Port 1 Pin 4
Safe state Port 0 Pin 4
-
Safe state Port 6 Pin 4
Safe state Port 5 Pin 4
Safe state
Port 4 Pin 4
Byte
2
3
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Sub-
index
12
11
10
9
16
15
14
13
Extension port
Description
Safe state Port 3 Pin 4
Safe state Port 2 Pin 4
Safe state Port 1 Pin 4
Safe state Port 0 Pin 4
Safe state Port 7 Pin 4
Safe state Port 6 Pin 4
Safe state Port 5 Pin 4
Safe state Port 4 Pin 4