EasyManua.ls Logo

Balluff BNI007Z - Identification Data Parameters; Parameter Data Settings

Balluff BNI007Z
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.balluff.com
29
6 Configuration extended with Valve Terminal Connector with 22/24 Valves
6.4. Parameter Data
/ Demand Data
DPP
ISDU
Parameter
Data
width
Access
rights
Default value
Index
Index
Sub-
index
Identification data
07hex
Vendor ID
2 bytes
Read only
0378hex
08hex
09hex
Device ID
3 bytes
05 0B 02hex
05 0B 03hex
05 0B 04hex
0Ahex
0Bhex
10hex
0
Vendor Name
7 bytes
BALLUFF
11hex
0
Vendor text
15 bytes
www.balluff.com
12hex
0
Product
name
BNI IOL-302-002-K006 with
BNI IOL-751-V08-K007
BNI IOL-302-002-K006 with
BNI IOL-751-V10-K007
BNI IOL-302-002-K006 with
BNI IOL-751-V13-K007
13hex
0
Product ID
20 bytes
BNI007Z with BNI006N
BNI007Z with BNI006P
BNI007Z with BNI006R
14hex
0
Product text
Sensor/Actor hub M12
extended with Valve plug
CG25 24 2-3
Sensor/Actor hub M12
extended with Valve plug
CG13 24 2-3
Sensor/Actor hub M12
extended with Valve plug
CG22-23 22 2-3
15hex
0
Serial number
16 bytes
0hex
16hex
0
Hardware
revision
17hex
0
Firmware
revision
18hex
0
Application-
specific tag
32 bytes
0hex
DPP
ISDU
Parameter
Data width
Access rights
Default
Value
Index
Index
Subindex
Parameter data
40hex
64
0
1-16
Inversion of the inputs
2 bytes
Read/write
0hex
41hex
65
0
1-16
Config. inputs/outputs
2 bytes
Read/write
0hex
42hex
66
0
1-32
Safe state on Pin 4
10 bytes
Read/write
0hex
43hex
67
0
1-8
Safe state on Pin 2
2 bytes
Read/write
0hex
44hex
68
0
1-23
Voltage monitoring
3 bytes
Read
-
45hex
69
0
1-40
Output monitoring
6 bytes
Read
-
46hex
70
0
1-16
Actuator warning
2 bytes
Read
-
54hex
84
0
Serial number
16 bytes
Read/write
16x00hex
55hex
85
0
Extension port
1 byte
Read/write
2, 3, 4hex