BSP - B010 - E V 002 - D 00 S 1 B - S4 - Z
Physical unit
M = millibar
W = millibar, vacuum (from –1 bar)
B = bar
V = bar, vacuum (from –1 bar)
K = kilobar
Max. pressure range (value correlates with phys. unit)
001 = 1
010 = 10
100 = 100
999 = 999
Process connection and housing
E = internal thread G1/4"
G = internal thread NPT 1/4"
I = external thread, flush-mounted G1/2"
Z = Special connection
Seal/sealing system (see BHS code)
N = Seal ring NBR
V = Viton gasket (ISO: FKM, DIN: FPM)
T = without, sealing via Triclamp
Housing type
002 = 1st generation D34x~90. Stainless steel pressure connection, display in
PA6, rotates 320°, process connection opposite display, el. connection on side
003 = 1st generation D34x~90. Stainless steel pressure connection, stainless steel
display, rotates 320°, process connection opposite display, el. connection on side
Interface to PLC
D = Digital data (switching point only)
Output function/output technology
00 = 2 x PNP, NO/NC selection
01 = 2 x NPN, NO/NC selection
Variant/options
S = IO-Link with SIO Mode
Subversions based on main version
1 = Basic variant
Operating elements
B = Display, 2 buttons
Connector system
S4 = M12, 4-pin
Special characteristics or design (optional)
Z = General special design
T = Temperature-resistant
006 =
Process connection Triclamp, FDA-conformal liquid, 3.1 Acceptance Test Certificate
Type code for pressure sensors with analog outputs
Pressure Sensors with IO-Link
BSP-B... /-V...