5.1 Starting up the system
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
Persons must keep away from the system's
hazardous zones.
Startup must be performed only by trained technical
personnel.
Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the transducer, if necessary.
Check for the correct values at the null point
and end point, especially after replacing the
transducer or after repair by the manufacturer.
5.2 Operating notes
Check the function of the position measuring system
and all associated components on a regular basis.
Take the position measuring system out of operation
whenever there is a malfunction.
Secure the system against unauthorized use.
5
Startup
BTL7-V50T-M ____ -P-C003
Micropulse Transducer in a Profile Housing

Other manuals for Balluff BTL7-V50D-M P-C003 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Balluff BTL7-V50D-M P-C003 Series and is the answer not in the manual?

Balluff BTL7-V50D-M P-C003 Series Specifications

General IconGeneral
BrandBalluff
ModelBTL7-V50D-M P-C003 Series
CategoryTransducer
LanguageEnglish

Related product manuals