Empty
nocom
Empty
nocom
20
B
A
Cartridges:
p. 18 - Empty output
11
Output: Empty [Empty]
As long as both cartridges are OK,
the contact is closed.
Via this two-output terminal blocks the controller notifies that at least one
cartridge in the attached fog generator is empty. This should be replaced with
a new cartridge as soon as possible.
HY -3 fog cartridges are available from your dealer or via the Bandit web site
www.bandit.be internet shop.
Properties of the Empty output [Empty].
In the case of at least one empty cartridge:
- Contact is open.
- The Empty LED lights.
- The front LED of the BANDIT fog generator will flash red
in order to indicate that there is a problem.
- For more information, see p. 26 .
This fog cartridge output [Empty] may be used in conjunction with the [OK]
output, or on its own (see example diagram 1 on page 32) to connect this
notification to a zone input of the controlling alarm system or an auto dialler
(to report the problem).
In this way an alert can be sent to all control centres (PAC's) to notify them
that at least one of the cartridges in the connected fog generator is empty.
F
The fog generator will always trigger a full cartridge when a fog ejection
has been requested (auto selection). Only when both cartridges are
empty (or not inserted correctly) will no fog ejection be possible.
BANDIT Controller CF31 v2 / Manual v.102