25 © Banner Engineering Corp. www.bannerengineering.com
PROFINET
®
6.4.1. Example Configuration
0x47 0x01
IO-Link In/Out 8/8
Byte + Status
12
x001 x005
Bidirectional
x506 x507
22
x051 x055
x851 x859
0x48 0x01
IO-Link In/Out 4/4
Byte + Status
8
x001 x003
Bidirectional
x506 x507
18
x051 x053
x851 x859
0x49 0x01
IO-Link In/Out 2/2
Byte + Status
6
x001 x002
Bidirectional
x506 x507
16
x051 x052
x851 x859
0x4A 0x01
IO-Link In/Out 1/1
Byte + Status
5
x001 x002
Bidirectional
x506 x507
15
x051 x052
x851 x859
0x4B 0x01 Digital Output 5
x051 x051
Output Module
x851 x851
x853 x853
x858 x858
0x4C 0x01 Digital Input
2 x001 x001
Bidirectional
4
x051 x051
x851 x851
x853 x853
x858 x859
Table 4: Slot 10 (ISDU)
Module ID Submodule ID Module
Size
(bytes)
Register
Start
Register
End
Direction
0x4D 0x01 ISDU 190 Byte + Status
196 351 442
Bidirectional
196 200 291
0x4E 0x01 ISDU 80 Byte + Status
86 351 396
86 200 245
Slot Module Description
Slot 1 Banner IO-Link Master Info
Vendor ID, Device ID, Number of Supported
Channels, and Firmware Version information
Slot 2 IO-Link In/Out 32/32 Byte + Status
Get/send IO-Link PDI/PDO for IO-Link device on Port
1 with PD Size between 17 and 32 bytes
Slot 3 IO-Link In/Out 16/16 Byte + Status
Get/send IO-Link PDI/PDO for IO-Link device on Port
2 with PD Size between 9 and 16 bytes
Slot 4 IO-Link In/Out 2/2 Byte + Status
Get/send IO-Link PDI/PDO for IO-Link device on Port
3 with PD Size between 1 and 2 bytes
Slot 5 Digital Output Use SIO Output mode on Port 4
Slot 10 ISDU 190 Byte + Status ISDU read/write access for all ports in IO-Link mode
Table 3: Slots 2-9 (1 per IO-link port) (Continued) (Sheet 2 of 2)
Module ID Submodule ID Module Size (bytes) Register Start Register End Direction