IO-Link Data Map
This document refers to the following IODD file: Banner_Engineering-Q5X-20180313-IODD1.1.xml. The IODD file and support files
can be found on
www.bannerengineering.com
, under the download section of the product family page.
Communication Parameters
The following communication parameters are used.
Parameter Value
IO-Link revision V1.1
Process Data In length 32 bits
Process Data Out length 8 bits
Bit Rate 38400 bps
Minimum cycle time 3.6 ms
Parameter Value
Port class A
SIO mode Yes
Smart sensor profile Yes
Block parameterization Yes
Data Storage Yes
IO-Link Process Data In (Device to Master)
Process Data In is transmitted cyclically to the IO-Link master from the IO-Link device.
Process Data (If Binary Data Is Included)
Process Data Input
Subindex Name Number of Bits Data Values
1 Channel 1 Output State 1 0 = inactive
1 = active
2 Channel 2 Output State 1 0 = inactive
1=active
3 Stability State 1 0 = no target/marginal
1 = stable
4 Measurement 1 Value 13 Value depends on "Configuration.Measurement 1
Selection"
5 Measurement 2 Value 16 Value depends on "Configuration.Measurement 2
Selection"
Octet 0
Subindex 5 5 5 5 5 5 5 5
Bit offset 31 30 29 28 27 26 25 24
Value 0 0 0 0 0 0 1 0
Octet 1
Subindex 5 5 4 4 4 4 4 4
Bit offset 23 22 21 20 19 18 17 16
Value 1 0 1 1 0 1 1 0
Octet 2
Subindex 4 4 4 4 4 4 4 4
Bit offset 15 14 13 12 11 10 9 8
Value 1 1 1 1 1 1 1 1
IO-Link Data Reference Guide: Q5X Sensor
Original Document
206834 Rev. B
7 February 2019