EasyManuals Logo

Banner Q5X Manual

Banner Q5X
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Quick Start Guide
Laser sensor with dual outputs and IO-Link
This guide is designed to help you set up and install the Q5X Laser Measurement Sensor. For complete information on
programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
www.bannerengineering.com. Search for p/n 208794 to view the Instruction Manual. Use of this document assumes familiarity with
pertinent industry standards and practices.
WARNING:
Do not use this device for personnel protection
Using this device for personnel protection could result in serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-
energized (off) output condition.
Features
The Q5X has three major features.
Figure 1. Q5X Features
1
2
3
1. Two output indicators (amber)
2. Display
3. Buttons
Display and Indicators
The display is a 4-digit, 7-segment LED. Run mode is the primary view displayed.
For 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in centimeters. For Dual TEACH
mode, the display shows the percentage matched to the taught reference surface. A display value of indicates the sensor
has not been taught.
Figure 2. Display in Run Mode
STB DYN FGS BGS
1
2
1. Stability Indicator (STB—Green)
2. Active TEACH Indicators
DYN—Dynamic (Amber)
FGS—Foreground Suppression (Amber)
BGS—Background Suppression (Amber)
Output Indicator
On—Output is on
Off—Output is off
Stability Indicator (STB)
On—Stable signal within the specified sensing range
Flashing—Marginal signal (low excess gain), the target
is outside the limits of the specified sensing range, or a
multiple peak condition exists
Off—No target detected within the specified sensing
range
Active TEACH Indicators (DYN, FGS, and BGS)
DYN, FGS, and BGS all off—Two-point TEACH mode
selected (default)
DYN on—Dynamic TEACH mode selected
FGS on—Foreground suppression TEACH mode
selected
BGS on—Background suppression TEACH mode
selected
DYN, FGS, and BGS all on—Dual TEACH mode
selected
Q5X Laser Measurement Sensor with Dual
Discrete Outputs and IO-Link
Original Document
208795 Rev. G
10 January 2023
208795

Other manuals for Banner Q5X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner Q5X and is the answer not in the manual?

Banner Q5X Specifications

General IconGeneral
BrandBanner
ModelQ5X
CategorySecurity Sensors
LanguageEnglish