88
density of electrolyte, put the sucker of the densimeter into the electrolyte vertically,
extruding the rubber tube with finger, then the electrolyte will be absorbed into the glass
tube, at last, the buoy of densimeter will float. Read the number of densimeter.
Note: The densimeter must be floated vertically, not lean to the glass tube.
6.3.5 Adding distilled water
(1) Get a certain amount of distilled water with a graduated container.
(2) Open all pouring caps of battery units.
(3) Absorb distilled water with ball type injector to charge the battery. When
electrolyte is over 15-20mm upper the plate, stop charging.
(4) After charging, tighten the pouring cap.
(5) Clean the surface of battery unit with a wet cloth.
Note: (1) Wear eyes-protect glasses, rubber overshoes and rubber gloves.
(2) When adding the distilled water, never exceed the appointed amount.
Adding too much will lead the leakage of electrolyte, then the truck will be damaged
when charging or discharging.
(3) When adding too much, draw out water with ball type injector.