27R5905753 /17 DPxK-19B/23B/P
2. Physical installation of the projector upon its pedestal and connecting the air outlet of the projector with
the exhaust system. Note that the exhaust system is MANDATORY. See chapters “Positioning the DPxK-
19B/23B/P at port window”, page 30, and “Installation of the exhaust system”, page 32.
3. Electrical connection with the power net. See chapter “Connecting the DPxK-19B/23B/P with the
power net”, page 35.
4. Installation of a suitable UPS unit or bypass the power in and outlet for the projector electronics. See
chapters “Power loop through to the projector electronics”, page 36 or “Connecting a UPS to the projector
electronics”, page 37.
5. Installation of the xenon lamp in case the xenon lamp is not installed in the lamp house yet. To install the
xenon lamp the lamp house has to be removed from the projector. To install the xenon lamp correctly and
in a safe manner, see the detailed step by step procedures in the chapter “Installation of the xenon lamp in
manual S/M Lamp House”, page 47.
6. Installation of the lens. First select an appropriate lens which throw ratio covers the screen size and the
projector - screen distance. Then install the lens in the lens holder of the projector. For more information
about available lenses, lens selection and lens installation see chapter “Lens installation”, page 62.
7. Installation of the Communicator Touch Panel. See chapter “Communicator Touch Panel”, page 129.
8. Installation of the HDDs. In case the HDDs of the ICMP are delivered separated from the projector
remove the protection tape from the HDD input slots and install all three HDDs as described in the
procedure “Installing a HDD into the ICMP(-X)”, page 104. Make sure that all HDDs in the ICMP(-X) HDD
set have the same storage capacity. See label on top of the HDD to know the storage capacity.
9. Alignment of the projected image on the screen. The projector can now be switched on to project its
first image (test pattern) on the screen. Then the image can be aligned with the screen size of the
application. Follow the next steps to achieve that:
1. Place the ON/OFF switch of the projector in the ”I” position. As a result the projector starts to initialize.
The status lights of the projector lights up GREEN once the projector is initialized.
2. Press the STANDBY button on the local keypad to activate the lamp.
3. Press the DOWSER button on the local keypad to open the dowser of the projector. The dowser is
open if the color of the DOWSER button is GREEN.
4. Press the TEST PATTERN button on the local keypad to project one of the internal test patterns of the
projector on the screen.
5. Use the lens ZOOM, SHIFT and FOCUS buttons on the local keypad the match the projected image
with the screen. Tilt the projector in case you can not SHIFT the image completely upon the screen.
See “Lens shift, zoom & focus”, page 65.
10. Resetting the lamp parameters. The “LAMP INFO” parameters which are stored on the controller board
of the projector MUST be updated after each installation of an xenon lamp inside the lamp house.
Neglecting this update will result in poor performance and short life time of the xenon lamp. See chapter
“Resetting the lamp parameters”, page 53.
11. Realignment of the xenon lamp in its reflector. For optimal performance of the xenon lamp it is required
to realign the lamp after installation in the lamp house. See “Realignment of the lamp in its reflector
(manual Lamp House)”, page 56 for more information.
12. Adjusting the light path. Normally the lens holder and the convergence of the projector is perfectly
adjusted at the factory. Nevertheless, some applications require a readjustment of the lens holder,
convergence or both. See procedure “Scheimpflug adjustment”, page 70, to adjust the Scheimpflug and
see “Convergence”, page 159 to adjust the convergence of the light path.
13. SCC calibration.
Note: A Spatial Color Calibration (SCC) has to be execute in case of a first install or in case a
High Brightness lens is swapped with a High Contrast lens or vice versa. See user guide of the
Communicator for detail SCC calibration instructions.
14. Registration of the projector. The DPxK B is DCI compliant and should be registered by Barco.
Therefore, the digital certificate inside the projector will be used to secure encryption key communication
between the projector and the rest of the theatre system (server and theatre management system).
15. Projection of a digital cinema movie.
In case the projector is equipped with an ICMP(-X), download the ICMP(-X) device certificate, request
KDM and DCP from your content supplier, ingest KDM and DCP, and play out the movie. for detailed
General