Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.
Multispeed blower motors for airflow adjustment; motor overload protection is standard.
Reciprocating or scroll compressor designed for higher ratios and longer operation.
20 gauge zinc-coated steel cabinet finished with baked-on enamel for durability.
Accessible through a right side service panel with lockable access cover.
Features automatic limit and thermal cut-off safety control; field installed.
Assembly slides out for easy access.
Standard 1-inch disposable filters; optional washable filters available.
Provides efficient defrost cycles with thermistor sensor and override.
Built-in lockout circuit that resets from the room thermostat.
Short cycle protection is standard and built into the heat pump control.
Protects reciprocating compressor from refrigerant flood back.
Permits continuous operation of the system.
Standard on all units, allows up to 25% outside fresh air.
Standard on electric heat versions; toggle disconnects on 460V.
Standard feature for water run-off.
Full length brackets built into cabinet for improved appearance.
Standard feature on all models.
Standard feature; allows up to 25% outside air, mixed with conditioned air.
Optional; covers air inlet openings, restricts outside air entry.
Optional; internally mounted, allows outside air, controlled by 24VAC motor.
Optional; allows up to 50% outside air, includes exhaust air damper.
Optional; provides "free cooling" when outside air is cool and dry.
Optional; meets IAQ requirements, provides heat transfer.
Cooling performance data for WERV-2B at various ventilation rates and ambient conditions.
Heating performance data for WERV-2B at various ventilation rates and ambient conditions.
Cooling performance data for WERV-3C at various ventilation rates and ambient conditions.
Heating performance data for WERV-3C at various ventilation rates and ambient conditions.
Cooling performance data for WERV-5C at various ventilation rates and ambient conditions.
Heating performance data for WERV-5C at various ventilation rates and ambient conditions.
Minimum clearances for service access on left and right sides of the unit.
Minimum clearances required to combustible materials for supply air duct and cabinet.
Nominal dimensions for unit width, depth, height, and port locations (A-T).
Details on single-circuit power, ampacity, fuses, and wire size.
Details on dual-circuit power, ampacity, fuses, and wire size.
Important notes on wire sizing, derating, and compliance with codes.
CFM data for indoor blowers at various ESP and voltage conditions.
Lists available electric heat KW, voltage, and Btuh ratings by unit model.
Part numbers and KW for field-installable electric heater packages.
Cooling capacity data at various ambient DB/WB and indoor conditions.
BTUH, COP, and HSPF ratings across different temperatures and applications.
Explanation of each component in the unit model number designation.
Table detailing available factory and field installed ventilation options.
Overview of available control modules for low pressure and low ambient control.