Installation
26
Operating Instructions Radiation sensors R3XX
3.3.1 Safety instructions for the operation of
Laserpointer type R300-101
To operate the Laserpointer type R300-101, please keep in mind the
following instructions:
The beam emitted by this LASER is strongly bundled.
Caution:
Do not look into the laser beam or at direct reflexes of reflecting or polished
surfaces - not even by means of optical instruments.
The working area has to be protected by suitable protective shields which
prevent the laser beam from leaving the protected area in an uncontrolled
way.
After the laser beam has crossed the setting range, it has to be blocked and
absorbed by means of a suitable shield.
Do NOT lead the laser beam at eye level.
Attach LASER warning signs at clearly visible locations next to all accesses
to the laser working area.
Caution:
Use of laser protective goggles is mandatory if you work with an open laser
beam.
The device should only be operated by persons who know these safety
instructions and are familiar with complying to them.
3.3.2 Safety instructions for the utilisation of
the IR protection window Zn-Se type
R300-136 (order no. 301954)
For the utilisation of the IR protection window ZnSe, observe the following
basic instructions:
The IR protection window contains zinc selenide (ZnSe).
Avoid any damage to the protection window.
Damaged filters can cause dust formation. Inhaling or swallowing dust or
splints can cause intoxication. Call a doctor in case of emergency.
For removing broken protection windows, wear gloves and in urgent
cases a respiratory protection mask and protection goggles.
Wear gloves to clean the window.
The protection window should only be replaced by persons familiar with
the safety instructions and observing them.