EN | UltraQ | Operating instructions EN | UltraQ | Operating instructions
The probes supplied with the UltraQ are precision
stainless steel thermocouple material.
The thermocouple wiring has an armoured braid with
moisture and smoke resistant teon insulation rated
for stationary temperatures up to 180 degrees. Avoid
kinking the wires and do not allow them to come into
contact with direct ame (heat spot). They should be
washed by hand. The probes can be replaced by the
user. Keep a spare set ready for unforeseen emergen-
cy situations.
03 PREMIUM SENSORS
PLEASE NOTE
1. Insert the sensors completely into the control unit.
Push the plugs into the sockets so that they phy-
sically and audibly snap into place. If the sensors
are not connected securely, incorrect temperature
readings may occur and the DynaQ will not regula-
te the temperature accurately. This can cause the
grill to go out
2. There is an LED indicator light above each sensor
socket. If a probe is rmly inserted into the socket
when the DynaQ is switched on, but the LED
does not light up, this indicates that the probe is
damaged or defective and does not indicate the
temperature correctly.
3. The cooking chamber temperature sensor must
be placed inside the grill near the cooking area for
proper temperature control. If this sensor is not in
the grill, there will be no control. This can lead to
the fan running constantly and the grill becoming
excessively hot.
4. Some ceramic grills can cause early probe failure
by using wires between the gaskets. If you use a
deector, we recommend routing the probe cables
through the exhaust cap. The heat that rises through
the gap between the outer wall and the deector is
intense and concentrated. If the cable is exposed
to this heat source, it can quickly become dama-
ged. For ceramic grills, it is recommended to use
the Gurus for Low & Slow jobs only. With proper
care, a probe has a functional expectancy of 2 to
3 years.
The fan system uses a variable flow rate to finely
modify the amount of oxygen supplied to the fire
and raises or lowers the air flow to maintain the
specified set temperature. All fans are equipped
with an adjustable „damper“ and an aluminium
nozzle. The „damper“ (sliding flap) can be closed
completely to extinguish the embers. This function
can be used to make fine adjustments for any wind
draughts, which could affect the grill temperature
during the fan‘s switch-off cycle. Open the “damper“
fully for a quick start. Close half to two thirds of the
„damper“ for smaller grills or low and slow
cooking.
04 VARIABLE
AIR FLOW RATE