Deleting the intermediate position II
1. Open/close the sun protection to the intermediate position II.
2. Simultaneously press and hold the STOP button and the retract button.
3. The sun protection shifts to confirm.
4. The intermediate position II is now deleted.
Deleting the intermediate positions
Press the STOP button twice within 0.5 seconds and then press and hold for
10 seconds.
The sun protection shifts to confirm.
All stored intermediate positions are now deleted.
Technical data
Rated voltage 230 V AC / 50 Hz
Switching current
5 A /250 V AC at cos =1
Battery type CR 2032
Degree of protection IP 20
Class of protection
(dependent on correct assembly)
II
Permissible ambient temperature 0 to +55 °C
Type of mounting Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing